GCP-500 offers a bandwidth of 500 kHz, suitable for applications in high-frequency switching power supplies and inverter systems. Includes overload protection for safe operation. Prioritizes external AC power to enhance measurement accuracy.
Product Introduction
The GCP-500 significantly extends measurement bandwidth to 500 kHz, making it ideal for applications requiring high-frequency current monitoring. It features an overload indicator and prioritizes external AC power operation.
Measurement Specification
- Bandwidth : DC to 500 kHz
- Current range : 30 mA to 150 A
- Sensitivity ranges : 150 A range: 20 mV/A, 15 A range: 200 mV/A
- Accuracy : ±3% (30 mA ~ 15 A range), ±4% to ±15% depending on current level
- Output : BNC, oscilloscope ready
- Max circuit voltage : CAT III 600 V
Product Features
- AC & DC current measurement : Yes
- Overload indicator : Yes
- External AC power priority : Yes
Product Information
- Power supply : 9 V battery, AC/DC adapter (automatic priority)
- Warning : Do not clamp onto circuits exceeding 600 VAC